Technical Information
Service Manual
Outdoor
Unit
Outdoor Unit Model GEH12AA-K3DNA1D/O GEH18AA-K3DNA1D/O
Outdoor Unit Product Code CV010W02600 CV010W02400
Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR
CO.,LTD
ZHUHAI LANDA COMPRESSOR
CO.,LTD
Compressor Model QXA-B102zE190 QXA-B141zF030
Compressor Oil RB68EP 68EP
Compressor Type Rotary Rotary
Compressor LRA. A / 18
Compressor RLA A 6.6 7.2
Compressor Power Input W 1020 1440
Compressor Overload Protector
1NT11L-6233 or HPC115/95U1 or
KSD115ºC
1NT11L-6233 or KSD115ºC or
HPC115/95U1
Throttling Method Electron expansion valve Electron expansion valve
Set Temperature Range ºC 16~30 16~30
Cooling Operation Ambient Temperature
Range
ºC -15~43 -15~43
Heating Operation Ambient Temperature
Range
ºC -22~24 -22~24
Condenser Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Φ7.94 Φ7
Condenser Rows-n Gap mm 2-1.4 2-1.4
Condenser Coil Length (LXDXW) mm 710X38.1X508 851X38.1X660
Fan Motor Speed rpm 900 800
Fan Motor Power Output W 30 60
Fan Motor RLA A 0.37 0.39
Fan Motor Capacitor μF / /
Outdoor Unit Air Flow Volume m
3
/h 1600 3200
Fan Type Axial-ow Axial-ow
Fan Diameter mm Φ400 Φ520
Defrosting Method Automatic Defrosting Automatic Defrosting
Climate Type T1 T1
Isolation I I
Moisture Protection IPX4 IPX4
Permissible Excessive Operating Pressure
for the Discharge Side
MPa 4.3 4.3
Permissible Excessive Operating Pressure
for the Suction Side
MPa 2.5 2.5
Sound Pressure Level (H/M/L) dB (A) 52/-/- 57/-/-
Sound Power Level (H/M/L) dB (A) 62/-/- 65/-/-
Dimension(WXHXD) mm 782X540X320 963X700X396
Dimension of Carton Box (LXWXH) mm 820X355X580 1026X455X735
Dimension of Package(LXWXH) mm 823X358X595 1029X458X750
Net Weight kg 31.5 46
Gross Weight kg 34 50.5
Refrigerant R410A R410A
Refrigerant Charge kg 0.95 1.3
Connection
Pipe
Connection Pipe Length m 5 5
Connection Pipe Gas Additional Charge g/m 20 20
Outer Diameter Liquid Pipe mm Φ6 Φ6
Outer Diameter Gas Pipe mm Φ9.52 Φ12
Max Distance Height m 10 10
Max Distance Length m 20 25
Note: The connection pipe applies metric diameter.