PRODUCT
8
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
DB, 19WB. Outdoor Temperature is 35DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20DB. Outdoor Temperature is 7DB, 6WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
4.2 Product Data of Indoor Unit
4.2.1 Wall mounted type
¾ Hansol
Model
GWH(07)TA-K3DN
A1E/I
GWH(09)TA-K3DN
A1E/I
GWH(12)TB-K3DN
A1E/I
Cooling kW 2.1 2.5 3.50
Capacity
Heating kW 2.6 2.75 3.65
Power supply V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50
Motor power input kW 0.029 0.029 0.029
m3/h 550 550 770
Air flow volume
CFM 324 324 430
Sound pressure level
(SH/H/MH/M/ML/L/SL)
dB(A) 41/36/34/32/28/24/21 41/36/34/32/28/24/21 43/36/34/32/28/24/21
Output kW 0.015 0.015 0.015
Fan motor
Running
current
A 0.07 0.07 0.07
Gas inch 3/8(Φ9.52mm) 3/8(Φ9.52mm) 1/2(Φ12.7mm)
Liquid inch 1/4(Φ6.35mm) 1/4(Φ6.35mm) 1/4(Φ6.35mm)
Connecting
pipe
Connection method Flare Connection Flare Connection Flare Connection
External dia. mm Φ20 Φ20 Φ20
Drain pipe
Thickness mm 1.5 1.5 1.5
Outline
dimension
W×D×H mm 806×209×292 806×209×292 866×209×292
Package
dimension
W×D×H mm 888×297×377 888×297×377 945×297×377
Net Weight/Gross weight kg 10.5/13.0 10.5/13.0 11.0/13.5
20'GP 266 266 252
40' GP 553 553 518
Loading quantity
40' HQ 632 632 592