EasyManua.ls Logo

Gree GKH(12)BA-K3DNA2A/I

Gree GKH(12)BA-K3DNA2A/I
207 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Super Free Match
Service Manual
PRODUCT
20
4.2.5 Console type
Model Heat pump
GEH(09)AA-K3DNA1
C/I
GEH(12)AA-K3DNA1
C/I
GEH(18)AA-K3DNA1
C/I
Cooling KW 2.6 3.5 5.3
Capacity
Heating KW 2.8 3.8 5.8
Power supply V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50
Motor power input kW 0.05 0.05 0.05
m3/h 500 600 650
Air flow volume
CFM 294 353 383
Sound pressure level
(SH/H/MH/M/ML/L/SL)
dB(A) 40/38/36/33/30/27/25 42/40/38/37/35/32/25 48/46/44/41/37/35/32
Output kW 0.03 0.03 0.03
Fan motor
Running
current
A 0.14 0.14 0.14
Gas inch 3/8(Φ9.52mm) 3/8(Φ9.52mm) 1/2(Φ12.7mm)
Liquid inch 1/4(Φ6.35mm) 1/4(Φ6.35mm) 1/4(Φ6.35mm)
Connecting
pipe
Connection method Flare Connection Flare Connection Flare Connection
External
dia.
mm Φ20 Φ20 Φ20
Drain pipe
Thickness mm 1.5 1.5 1.5
Outline
dimension
W×D×H mm 700×215×600 700×215×600 700×215×600
Package
dimension
W×D×H mm 791×286×710 791×286×710 791×286×710
Net Weight/Gross weight kg 15/18 15/18 15/18
20'GP 168 168 168
40' GP 348 348 348
Loading quantity
40' HQ 440 440 440
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
DB, 19WB. Outdoor Temperature is 35DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20DB. Outdoor Temperature is 7DB, 6WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.