EasyManua.ls Logo

Gree GMV-450WM/H-X User Manual

Gree GMV-450WM/H-X
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Owner's Manual
Original Instructions
Commercial Air Conditioners
GMV DC Inverter VRF
Models:
GMV-224WM/H-X
GMV-280WM/H-X
GMV-335WM/H-X
……
GMV-2460WM/H-X

Questions and Answers:

Gree GMV-450WM/H-X Specifications

General IconGeneral
BrandGree
ModelGMV-450WM/H-X
CategoryInverter
LanguageEnglish

Summary

To Users

Exception Clauses

Safety Notices

Product Introduction

Product Features

Highlights the key technological advantages and design aspects of the system.

Product List

Details the various outdoor unit models and their combinations.

Names of Main Parts

Product Working Principle

Working Principle Introduction

Describes the system's cooling and heating cycle logic.

Working Principle Diagram

Visual representation of the system's refrigeration circuit.

Working Temperature Ranges

Product Installation

Safety Precautions for Installation

Essential safety guidelines for installing, repairing, and moving units.

Outdoor Unit Installation

Product Size Drawing

Dimensional drawings and specifications for outdoor units.

Select Installation Position

Seasonal Wind Considerations

Advice on installing outdoor units considering seasonal wind effects.

Snow Considerations

Guidance on accounting for snow when installing outdoor units.

Installation Space Requirements

Installation Space Requirements for Equipment Floor

Installation Foundation

Shock Absorption Requirements

Guidelines for securing outdoor units with vibration damping.

Pipeline Design

Notices for Pipeline Design

Key guidelines for safe and efficient refrigerant pipe installation.

Pipeline Requirement

Allowable Pipe Length and Height Difference

Specifications for pipe lengths and vertical/horizontal differences between units.

Pipeline Installation and Insulation

Pipeline Installation of Refrigeration System

Procedures for installing refrigerant piping, including welding and bending.

Manifold Installation

Steps and considerations for installing refrigerant distribution manifolds.

Refrigerant Pipe Insulation

Pipeline Wrapping

Methods for insulating refrigerant pipes to prevent condensation and heat loss.

Static Pressure Ventilation Pipe Installation

Preparation for Ventilation Pipe Installation

Steps to prepare for installing ventilation ducts for outdoor units.

Vacuum and Drying of Refrigeration System

Air Tightness Test

Procedure for testing the system's integrity against leaks using pressure.

Vacuum Drying

Steps to remove moisture and air from the refrigeration system.

Additional Refrigerant Charging

Calculation Method of Adding Refrigerant

Formula and method for calculating the correct amount of refrigerant.

Refrigerant-Charging Method

Precautions on Refrigerant Leakage

Electrical Installation

Notices for Electrical Installation

Guidelines and requirements for safe and compliant electrical installation.

Electrical Parameters

Power Cord Connection

Power Cord Installation Procedures

Steps for correctly connecting the power cord to the unit.

External Wiring Diagram

Diagrams illustrating the external electrical connections for the system.

Communication Line Connection

Connection Method of Communication Line Terminal

How to connect communication lines to terminal blocks.

Communication Material Selection

Recommended types of cables for communication lines.

Communication Address Setting

Communication Connection between IDU and ODU

Communication Connection Between Indoor Unit and Wired Controller

Other Communication Connection Methods

Check Items after Installation

Debugging and Operation

Preparation before Test Run

Procedures and checks required before performing system debugging.

Notices for Unit Debugging

Basic Introduction for Engineering Debugging

Debugging Method

Overview of the different methods for debugging the VRF system.

Debugging Through the Main Board of Outdoor Unit

Detailed steps for performing debugging using the outdoor unit's main control board.

Parameter Judgment Reference Value for Unit Normal Operation

Operation Instruction

Maintenance

Heat Exchanger of Outdoor Unit

Instructions for cleaning the outdoor unit's heat exchanger.

Drain Pipe

Precautions at the Beginning of Using Season

Maintenance at the End of Using Season

Parts Replacement

Troubleshooting

Common Malfunction and Troubleshooting

A guide to identifying and resolving common operational issues and errors.

Error Indication

After-sales Service

Related product manuals