Owner's Manual
Original Instructions
Commercial Air Conditioners
GMV DC Inverter VRF
Models:
GMV-224WM/H-X
GMV-280WM/H-X
GMV-335WM/H-X
……
GMV-2460WM/H-X

Questions and Answers

  • M
    Mike WilkersonJul 26, 2025
    What to do if Gree GMV-504WM/H-X Inverter has abnormal cooling or heating?
    • J
      Jill DavisJul 26, 2025
      If your Gree Inverter is showing abnormal cooling or heating, close any open doors or windows and draw any curtains or louvers to block direct sunlight. Reduce the number of heat sources in the room. Also, clean the filter if it is blocked with dirt.
  • M
    Mario PierceAug 1, 2025
    Why is my Gree Inverter cooling or heating abnormally?
    • T
      Tanya LeeAug 1, 2025
      If your Gree Inverter is not cooling or heating properly, check that the air intake and outlet of both the indoor and outdoor units are free from obstructions. Also, make sure the temperature setting, fan speed, and wind direction are properly adjusted using the wireless remote controller or wired controller.
  • S
    Shawn JamesAug 10, 2025
    How to troubleshoot a Gree Inverter that doesn't run?
    • S
      Sandra OrrAug 10, 2025
      If your Gree Inverter isn't running, first ensure it's properly connected to a power supply. Then, verify that the voltage is within the specified range. Check the fuse and breaker, replacing the fuse or reconnecting the breaker if necessary. Also, replace the batteries in the remote controller. Finally, make sure you are within the 8m control range of the remote.
  • C
    Christy StoneAug 17, 2025
    What to do if Gree Inverter runs but stops immediately?
    • N
      nmckenzieAug 17, 2025
      If your Gree Inverter runs but stops immediately, the air intake or outlet of either the indoor or outdoor unit might be blocked. Remove any obstructions to resolve this issue.

Summary

Safety Notices

Product Installation

Safety Precautions for Installing, Repairing and Moving Units

Lists critical safety measures for installation, repair, and moving of the units.

Outdoor Unit Installation

Select Installation Position

Provides conditions for selecting the optimal installation position.

Installation Space Requirements

Pipeline Design

Allowable pipe length and height difference

Specifies maximum pipe lengths and height differences.

Pipe Selection

Pipeline Installation and Insulation

Vacuum and Drying of Refrigeration System

Air Tightness Test

Details the procedure for performing an air tightness test.

Vacuum Drying

Provides requirements and procedures for vacuum drying the refrigeration system.

Additional refrigerant charging

Calculation Method of Adding Refrigerant

Explains how to calculate the total refrigerant charging amount.

Refrigerant-charging Method

Details the step-by-step process for pre-charging refrigerant.

Start-up charging of refrigerant

Describes the procedure for charging refrigerant after initial pre-charging.

Precautions on Refrigerant Leakage

Electrical Installation

Notices for Electrical Installation

Provides crucial safety notices and requirements for electrical installation.

Electrical Parameters

Lists power supply specifications, circuit breakers, and wire sizes.

Communication Line Connection

Communication Line Connection

Details series connection requirements for communication bus.

Check Items after Installation

Debugging and Operation

Preparation before Test Run

Details necessary preparations before conducting the test run.

Notices for Unit Debugging

Provides important notices and precautions to follow during debugging.

Basic Introduction for Engineering Debugging

Parameter Judgment Reference Value for Unit Normal Operation

Troubleshooting

Common Malfunction and Troubleshooting

Lists common issues, causes, and solutions.

Error Indication

Gree GMV-504WM/H-X Specifications

General IconGeneral
CategoryInverter
Cooling Capacity14.0 kW
Heating Capacity16.0 kW
Power Supply380-415V/3Ph/50Hz
RefrigerantR410A
COP3.6
Indoor Unit Noise Level42 dB(A)