EasyManua.ls Logo

Gree GMV-504WM/G-X - User Manual

Gree GMV-504WM/G-X
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Owner's Manual
Original Instructions
Commercial Air Conditioners
GMV DC Inverter VRF
Models:
GM
V-224WM/G-X
GMV-280WM/G-X
GMV-335WM/G-X
……
GMV-2720WM/G-X

Other manuals for Gree GMV-504WM/G-X

Questions and Answers

  • M
    Mary MitchellAug 9, 2025
    Why my Gree Air Conditioner unit doesn’t work?
    • L
      Lawrence VasquezAug 9, 2025
      Your Gree Air Conditioner might not be working due to several reasons: a cut-off fuse or circuit breaker (replace the fuse or reset the circuit breaker); a power failure (restart the unit when power is restored); disconnected power supply (connect the power); insufficient remote controller power (replace the battery); or the remote controller being out of range (ensure it's within 8m).
  • L
    Lisa SmithAug 19, 2025
    What to do if my Gree Air Conditioner has abnormal cooling or heating?
    • A
      Anna BellAug 19, 2025
      If your Gree Air Conditioner isn't cooling or heating properly, check for these possible causes: blocked air inlets or outlets (clear any obstructions); improper temperature, fan speed, or wind direction settings (adjust via the remote or wired controller); open doors or windows (close them); direct sunshine (use curtains or louvers); too many people or heat sources in the room (reduce these); or a blocked and dirty filter (clean the filter).
  • T
    Tracy KimAug 30, 2025
    What to do if my Gree Air Conditioner runs but stops immediately?
    • D
      David PattersonAug 30, 2025
      If your Gree Air Conditioner starts but stops right away, it might be because the air inlet or outlet of the indoor or outdoor units is blocked. Clear any obstructions to resolve this.

Summary

Safety Notices

Installation and Operation Safety Guidelines

Guidelines for safe installation, operation, maintenance, and handling of refrigerant.

Product Installation

Installation Safety Precautions

Crucial safety guidelines for installation, repair, and movement of the unit and its components.

Pipeline Design and Installation

Refrigeration System Procedures

Vacuum, Drying, and Air Tightness Testing

Procedures for vacuum drying, leak testing, and ensuring system integrity.

Refrigerant Charging and Leakage Precautions

Methods for calculating and charging refrigerant, plus safety measures against leaks.

Electrical and Communication Systems

Electrical Installation and Wiring

Safety notices, parameters, power cord connections, and wiring diagrams for electrical systems.

Debugging and Operation

Installation Checks and Test Run Preparation

Lists essential post-installation checks and preparations for initial system testing.

Maintenance and Troubleshooting

Troubleshooting Common Issues and Errors

Lists common problems, causes, solutions, error codes, and their meanings.

Gree GMV-504WM/G-X Specifications

General IconGeneral
CategoryInverter
Cooling Capacity50.4 kW
Power Supply380-415V/3Ph/50Hz
RefrigerantR410A
Outdoor Unit Noise Level68 dB(A)
Heating Capacity56 kW
Energy Efficiency Ratio (Cooling)3.5
Operating Temperature Range (Cooling)-5°C to 48°C
Operating Temperature Range (Heating)-20°C to 24°C