GREE DC Inverter Multi VRF System II Service Manual
121
Removal operation of compressor
Remark: Before removing the compressor, please make sure that there’s no refrigerant inside the pipeline and the power
is disconnected.
Process
Photo
Operation Instruction
5. Fix the new
compressor at the
chassis
After re
placing the
compresor, fix the
nuts at the bottom of
compressor
6. Connect suction
pipe and discharge
pipe of copressor
and pipeline of
system again
Weld the connection
pipe of compressor,
connect the pipeline
and compressor
Note: During welding
process
, do not let
flame burn out other
parts
7. Connect the
power cord of
compressor well
● Loose screws fixing
the power cord with
screwdriver
● conenct the power
cord well again
Note: When
connecting the power
cord, make marks for
different color power
cords and
corresponding wiring
terminals.
8. Check and open
the upper cover
plate
●Check
whether the
pipeline is connected
well
●Check whetehr all
parts and connection
wires are connected
well
●If there’s no problem
after checking, install
front and rear cover
plates.