Installation Precaution
Requirement of air conditioner
Requirements for electric connection
Safety precaution
1. The place with strong heat sources, vapors, fla-
2.
Basic requirement
Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the
local dealer:
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7.
1.
Air inlet should be far away from obstacles and do
It’s not allowed to be installed on the unstable or
mmable or explosive gas,or volatile objects spread
in the air.
The place with high-frequency devices (such as
welding machine, medical equipment).
2. Select a location where the noise and outflow air
3. Please try your best to keep far away from fluor-
not put any objects near air outlet. Otherwise, it
will affect the radiation of heat discharge pipe.
emitted by the outdoor unit will not affect neighb-
orhood.
escent lamp.
4.
1.
motive base structure (such as truck) or in the
corrosive environment (such as chemical factory).
The appliance shall not be installed in the laundry.
installing the unit.
2. According to the local safety regulations, use qu-
alified power supply circuit.
3. For appliances with type Y attachment, the instr-
Must follow the electric safety regulations when
4.
uctions shall contain the substance of the following.
grounding wire of power socket.
5. Be sure to cut off the power supply before proce-
eding any work related to electricity and safety.
6. Do not put through the power before finishing in-
stallation.
7. The air conditioner is first class electric appliance.
It must be properly grounding with specialized gr-
If the supply cord is damaged,it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Properly connect the live wire, neutral wire and
8.
ounding device by a professional. Please make
sure it is always grounded effectively, otherwise
it may cause electric shock.
The yellow-green wire or green wire in air conditi-
oner is grounding wire, which can't be used for
other purposes.
9. The grounding resistance should comply with na-
tional electric safety regulations.
10.
sheet:
with national wiring regulations.
11.To be in compliance with IEC 61000-3-11, impe-
dance value of power-supply system connected
The appliance shall be installed in accordance
to product must be less than or e qual to the all-
owable maximum value of |Zsys| in the following
0.13
GPH12AO-K5NNA1A
GPC12AO-K5NNA1A
WARNING
Observe all governing codes and ordinances.
Do not use damaged or non-standard power cord.
Be caution during installation and maintenance. Pr-
Selection of installation location
ohibit incorrect operation to prevent electric shock,
casualty and other accidents.