Chapter Ⅲ Debugging and Operation(4. Debugging Operation)
52
4.4 Finish Debugging Operation
Record the unit operation parameters
Debugging operation parameters
Rated capacity of outdoor
unit(kW)
Max difference between
ODU and water tank(m)
Debugging status: □ water heating
Before turning
on the unit
Outdoor ambient
temperature
Temperature of water
outlet pipe temperature
sensor
Temperature of water
tank temperature sensor
4.5 Unit Normal Operation Parameters Judgment Reference
(Debugging Detection)
During operation, as the difference between water temperature and ambient temperature, the
suction temperature, discharge temperature and compressor current may vary. When ambient
temperature rises, suction temperature and compressor current will increase. When water
temperature increases, discharge temperature and compressor current will increase. Actual