AIR SOURCE HEAT PUMP WATER
HEATER SERVICE MANUAL
T1/R134A/50Hz
(GC201510 - I)

Questions and Answers

  • B
    Brandi HuntAug 11, 2025
    What to do if Gree Water Heater shows E1 High Pressure Protection?
    • D
      David SmithAug 12, 2025
      The E1 error code on your Gree Water Heater indicates high pressure protection. This can be due to several reasons: a poor connection of the water tank temperature sensor, a loose pressure switch cable, a faulty pressure switch, or a mainboard fault. Try these solutions: Ensure the thermo-bulb is properly installed, re-connect the cable for the pressure switch, replace the pressure switch, or replace the mainboard.
  • D
    dennis03Aug 19, 2025
    What does E6 Communication Fault mean on a Gree Water Heater?
    • L
      lcruzAug 19, 2025
      An E6 Communication Fault on your Gree Water Heater suggests a problem with communication. This could be due to an exception or incorrect connection of the communication cable, a display fault, or a mainboard fault. Try these solutions: Re-connect the communication cable, replace the communication cable, or replace the wired controller.
  • T
    Teresa KnoxAug 26, 2025
    What to do if Gree SXD200LCJW/C1-K displays F3, F4, F6, Fd, FE, FL Temperature sensor Fault?
    • A
      Alexandra MckinneyAug 26, 2025
      If your Gree Water Heater is showing an F3, F4, F6, Fd, FE, or FL error, it indicates a temperature sensor fault. This could be due to an incorrect connection of the temperature sensor, a faulty temperature sensor, or a mainboard fault. Try these solutions: Re-connect the thermo-bulb, replace the thermo-bulb, or replace the mainboard.
  • S
    stacymoranSep 3, 2025
    Why is my Gree SXD200LCJW/C1-K Water Heater showing E4 Air Exhaust Protection?
    • B
      Brenda RiveraSep 3, 2025
      The E4 error code on your Gree Water Heater indicates air exhaust protection. This may be due to an air exhaust temperature sensor fault, refrigerant leakage, or insufficient refrigerant. To resolve this, try the following: Replace the thermo-bulb, repair welding and perfuse refrigerant again, or add refrigerant to the unit.

Gree SXD200LCJW/C1-K Specifications

General IconGeneral
ModelSXD200LCJW/C1-K
CategoryWater Heater
TypeHeat Pump Water Heater
Capacity200L
Rated Water Temperature55 °C
Max Water Temperature60 °C
RefrigerantR134a
Operating Temperature Range-7°C to 43°C