AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
4
5
Finned tube
exchanger
Provides heat exchange channel for refrigerant and air.
6 Fan motor
Enhances heat exchange on the air side of the finned tube exchange
and provides a low-temperature heat source continuously.
7 Filter
Filters impurities in refrigerant to protect components with small
diameter.
4 PRODUCT PARAMETERS
4.1 Product Parameters of Split type unit
4.1.1 Product Parameters of Outdoor Unit
Model GRS-S3.0G/NbA-K
Product code - ER02000130
Rated Heating Capacity
(
*
)
W 2800
Rated Input Power
(
*
)
W 700
COP
(
*
)
W/W 4.00
Load Profile - L
COP
DHW
(
**
)
W/W 2.90
Energy Efficiency Class
(
**
)
- A
Water Heating Energy Efficiency
(
**
)
- 110%
Annual electricity consumption
(average climate conditions)
kWh 878
Maximum Input Power W 1180+1500W (Electric Heater)
Outlet Water Temperature Default: 55 , 35 ~70
Power Supply - 220V-240V ~50Hz
Insulation Level -
Protection of Ingression -
PX4
Refrigerant
Name R134a
Charge kg 1.20
Outline Dimensions W x D x H mm
Package Dimensions W x D x H mm
Net Weight kg 35.5
Sound Power Level
(
***
)
dB(A) 61
Operating Range -7~45
Notes:
(
*
)
Value obtained
(
**
)
, as per EN16147, (EU)
No 814/2013.
(
***
)
Value obtained as per EN 12102-2008.
Under fast water heating mode, electric heater helps to heating water.