Heat Pump Pool Heater
14
branch leakage devices shall be installed.
(17) The connection method of the unit and the power cord and the interconnection
method of each independent component shall be subject to the circuit diagram
attached to the unit body.
(18) All wiring must use crimping terminals or single-core wires. The direct
connection of multi-stranded wires with the terminal block may cause a spark.
(19) Do not change the internal wiring of the unit at will, otherwise, our company
may not assume relevant legal responsibilities in case of relevant losses.
(20) The model and rating of the fuse shall be subject to the silk screen
identification on the corresponding controller or fuse sleeve.
(21) Communication cables should be laid out through cabling through, conduit
tube or cable channel.
3.2 Unit Installation Diagram
Fig. 3.2-1 Unit installation diagram
3.3 Dimensional Requirements of Installation Space
(1) The dimensional requirements of installation space of the unit are shown in the
figure below.
(2) The installation distance of the unit from the swimming pool shall not exceed
15 m.
(3) The heat pump must be installed at a minimum distance from the pool in
compliance with NFC15-100 (3.5 m from the water for France) or in
compliance with installation standards applicable in other countries.