Heat Pump Pool Heater
17
3.6.3.3 Wire Controller Connection
The wire controller is installed on the front panel of the unit by default. When it
needs to be adjusted to other places outside the unit, to be in compliance EN 55014,
the length of the communication cable between the wired controller and the unit
can't be more than 8m. The following steps need to be followed:
(1) Use a screwdriver to remove the fixing screw at the bottom of the wire
controller mounting box on the front panel, and lift the cover.
(2) Insert a screwdriver into the hole under the installation box, pry the wire
controller out of the installation box, pull out the connecting line, pull out the
docking terminal, and take out the wire controller.
(3) Cover the mounting box cover and fix the screws.
(4) Open the cover of the electrical box on the right board and connect the wire
controller to the H1 & H2 terminals corresponding to the wiring board. See the
manual of the wire controller for details.