Air-to-water Heat Pump
Thank you for choosing commercial air conditioners. Please read
t
his Owner s Manual carefully before operation and retain it for
f
uture reference.
If
you have lost the Owner's Manual,please contact the local agent
or
visit www.gree.com or send an email to global@gree.com.cn for
t
he electronic version.
GREE PRODUCTS, S.L.
Owner's Manual
Original Instructions
Air Conditioners
MONOBLOC
TYPE

Table of Contents

Other manuals for Gree GRS-CQ16Pd/NhG-K

Questions and Answers

  • T
    Thomas FloresAug 5, 2025
    What to do if Gree Heat Pump does not heat although compressor is running?
    • S
      srussellAug 5, 2025
      If your Gree Heat Pump isn't heating despite the compressor running, a possible cause is refrigerant leakage, which requires leakage detection and refrigerant replenishment. Another potential cause is a malfunctioning compressor, which would need replacement.
  • C
    Christopher ShafferAug 9, 2025
    How to improve hot water heating efficiency of Gree Heat Pump?
    • C
      Caleb FernandezAug 9, 2025
      If your Gree Heat Pump has poor hot water heating efficiency, check for poor heat insulation in the water system and enhance it. Also, check for poor heat exchange of the evaporator by ensuring normal air flow and cleaning the evaporator. Poor refrigerant levels due to leaks can also cause this, so check for refrigerant leaks. Finally, a blockage in the heat exchanger on the water side can reduce efficiency; clean or replace the heat exchanger if needed.
  • T
    Theresa PatelAug 13, 2025
    What causes heavy noise of Gree GRS-CQ16Pd/NhG-K Heat Pump compressor?
    • F
      fandersonAug 13, 2025
      Heavy noise from the Gree Heat Pump compressor can occur if liquid refrigerant enters the compressor, leading to liquid slugging. Check the expansion valve and temperature sensor for failures or looseness, and repair if necessary. Alternatively, internal parts in the compressor may be broken, requiring compressor replacement.
  • Y
    Yvonne GarciaAug 17, 2025
    What to do if Gree GRS-CQ16Pd/NhG-K Heat Pump fan makes a heavy noise?
    • H
      harryhansenAug 18, 2025
      If the Gree Heat Pump fan is making excessive noise, it could be due to a loose fixing bolt, which needs to be re-fixed. Alternatively, the fan blade might be touching the shell or grill, requiring adjustments. Unreliable fan operation may also cause noise, indicating the fan needs replacement.
  • H
    hcoleAug 22, 2025
    What to do if Gree Heat Pump water pump does not run?
    • C
      Christopher MorrisonAug 22, 2025
      If the Gree Heat Pump water pump isn't running or is running abnormally, it could be due to a malfunction in the power supply or terminal, requiring you to find out the reasons and repair it. A malfunctioning relay could also be the cause, necessitating a relay replacement. Another potential issue is air in the water pipe, which needs to be evacuated.
  • H
    Heidi WeissAug 27, 2025
    Why won't my Gree GRS-CQ16Pd/NhG-K compressor start?
    • L
      Leslie JacksonAug 27, 2025
      If the Gree Heat Pump compressor isn't starting, it could be due to a power supply issue such as a reversed phase sequence. It may also be due to loose connection wires, which should be checked and re-fixed. A malfunction of the mainboard or the compressor itself could also be the cause, requiring repair or replacement, respectively.
  • I
    iedwardsAug 30, 2025
    Why does my Gree GRS-CQ16Pd/NhG-K compressor start and stop frequently?
    • C
      christina00Aug 30, 2025
      If your Gree Heat Pump compressor frequently starts and stops, it could be due to poor or excess refrigerant; in this case you should discharge or add part of the refrigerant. It might also be caused by poor circulation in the water system, potentially due to blockages or air, so inspect the water pump, valve, and pipeline, cleaning the water filter or evacuating air as needed. A low load can also cause this issue; try adjusting the load or adding accumulating devices.

Summary

User Guidance and Safety Information

To Users

Important introductory information and responsibilities for users of the heat pump.

Safety Notices and Warnings

Essential safety instructions, warnings, and notes for safe operation and installation.

Handling Flammable Refrigerants

Safety procedures and precautions related to flammable refrigerants like R32.

Unit Description and Operation

Operating Principle of the Unit

Explanation of the unit's functions in cooling, heating, and water heating modes.

Nomenclature and Components

Identification of model codes, parameters, main components, and unit specifications.

Installation Guide

Installation Examples

Illustrative cases for connecting under-floor coils, water tanks, and FCUs.

Monobloc Unit Installation Guidelines

Instructions for unit location, dimensions, precautions, and pipe connections.

Hydraulic Unit and Water Tank Installation

Details on hydraulic connections, water tank setup, and water quality.

Electrical Wiring and Commissioning

Power Supply Wire and Leakage Switch Specifications

Recommended power cable specifications and leakage switch types.

Wiring Diagrams and Control Board Layout

Control board wiring, electrical specifications, and terminal board connections.

Commissioning and Test Run

Procedures for pre-startup checks, test runs, and unit acceptance.

Operation, Maintenance & Service

Daily Operation and Maintenance

Guidance on routine operation, maintenance, and troubleshooting.

Refrigerant Handling and Service

Procedures for refrigerant recovery, decommissioning, and service.

Gree GRS-CQ16Pd/NhG-K Specifications

General IconGeneral
Heating Seasonal Performance Factor (HSPF)4.0
RefrigerantR410A
Voltage220-240 V
Energy Efficiency Ratio (Cooling)3.21
Frequency50 Hz