Air-to-water Heat Pump
57
MONOBLOC
TYPE
Code Indication Error Name Source of Error Signal Control Description
FE
The rst sanitary water
tank temperature sensor
error
The plug on temperature
sensor is not correctly
connected to the socket
on mainboard.
The resistance of
temperature sensor
is not correct.
It will be automatically
cleared after the failure is
removed.
F3
Gas pipe temperature
sensor inside refrigerant
error
The plug on temperature
sensor is not correctly
connected to the socket
on mainboard.
The resistance of
temperature sensor
is not correct.
It will be automatically
cleared after the failure is
removed.
F0
Remote room temperature
sensor error
The plug on temperature
sensor is not correctly
connected to the socket
on mainboard.
The resistance of
temperature sensor
is not correct.
It will be automatically
cleared after the failure is
removed.
Ec Water switch error
The switch is damaged.
The wire of the
switch is loose.
The position of the
switch is wrong
It will be cleared after the
unit is turned o󰀨.
E2
Indoor anti-frozen
protetion
The resistance of
temperature sensor
is not correct.
The electronic
expansion valve can
not work normally.
It will be cleared once
malfunction is removed or it
will be shown all the time; but
it will be cleared immediately
when switching operation
mode.
Ed
outlet temperature High-
temp protection
The resistance of
temperature sensor
is not correct.
The plug on temperature
sensor is not correctly
connected to the socket
on mainboard.
Mainboard of outdoor
unit is damaged.
De-energize the unit and
then, energize it again. If the
malfunction is removed, the
code will be cleared.
EH
the rst internal electric
heater connection
Malfunction
The AC contactor
is damaged.
De-energize the unit and
then, energize it again. If the
malfunction is removed, the
code will be cleared.
EH
second internal electric
heater connection
Malfunction
The AC contactor
is damaged.
De-energize the unit and
then, energize it again. If the
malfunction is removed, the
code will be cleared.
EH
sanitary water tank
electric heater connection
Malfunction
The AC contactor
is damaged.
De-energize the unit and
then, energize it again. If the
malfunction is removed, the
code will be cleared.