GREE DC INVERTER HEAT PUMP CONDENSING UNIT SERVICE MANUAL
103
Model: GUD24W2/D-D(U), GUD30W2/D-D(U), GUD36W2/D-D(U)
Removal of Electronic Expansion Valve
Removing the electronic expansion valve, make sure there is no refrigerant in the pipeline and power is cut off.
Step Picture Work Instruction
1. Remove the
electric box.
Remove the upper, lower and
front panels.
Loosen the wire clamp at the
bottom of the electric box
Unscrew the screws of
electric box.
The connection wires inside
and outside the electric box
should be removed.
When removing the electric
box, be careful to protect the
components.
2. Remove the fixed
block.
Remove the fixed block
between the electronic
expansion valve and the
pipe.