GREE DC INVERTER HEAT PUMP CONDENSING UNIT SERVICE MANUAL
43
Troubleshooting
3.4.17 “H5” IPM module current protection
Error display:
ODU mainboard LED displayer
Error judgment condition and method:
When power is connected and drive chip received IPM lead F0 that is of low level, than it is IPM module
malfunction. System will shut down for protection.
Possible reason:
Compressor 3-phase wire connection is lack of phase or phase-reversed.
System is overloaded and compressor current is too large.
Drive board IPM module is damaged.
Drive board IPM module’s 15V power supply is lower than 13.5V.
Drive board 6-line PWM signal and the corresponding element are abnormal.
Drive board compressor current sampling circuit element is damaged or drive chip current sampling AD
terminal is abnormal.
Compressor is damaged.