GREE                                                                                                    U-Match 5 SERIES UNIT SERVICE MANUAL
 
89 
 
Removal of electronic expansion valve 
Note: Before removing the electronic expansion valve, make sure there is no refrigerant in the pipeline and power is cut off. 
5. Install the new electronic 
expansion valve. 
●Weld the connection pipe of 
electronic expansion valve.   
●When welding the electronic 
expansion valve, the valve should 
be wrapped with wet cloth.     
●Nitrogen welding: the pressure of 
nitrogen is 0.5±0.1kgf/ c  ㎡ 
(relative pressure). Note: When 
welding the pipes, do not let the 
flame burn the other components. 
●Install the coil of electronic 
expansion valve.   
6. Secure the electric box 
and arrange the wires as 
required. 
●Put the electric box back in place 
and tighten up the screws. 
●Arrange the wires as original.   
7. Check and install the 
panels. 
●Check whether each component 
and connection wire is well 
connected.   
●If everything is OK, install the 
upper, left and right panels. 
Tighten up the screws.