86
U-MATCH Air
Conditioners
Service Manual
Cassette Type Indoor Unit’s Error Indicating:
LED No error
Flash times
every two
seconds
Error description
yellow: Timing
indicating lamp
It goes on as per the
VHWWLPH$QGLWÀDVKHV
when the temperature
sensor error occurs
once the indoor ambient temperature sensor error
twice the evaporator temperature sensor error
three times the condenser temperature senor error
four times the outdoor ambient temperature senor error
¿YHWLPHV the discharge air temperature sensor error
green:Compressor
indicating lamp
It goes on/off as the
compressor is turned
RQRII$QGLWÀDVKHV
when defrosting or the
compressor error occurs
twice Defrosting
three times high pressure protection
four times the low pressure protection
¿YHWLPHV Overload protection
six times Discharge high temperature protection
red:Running
indicating lamp
It goes on/off as the
unit is turned on/off,
$QGLWÀDVKHVZKHQWKH
indoor unit error occurs
twice WKHZDWHURYHUÀRZSURWHFWLRQ
three times the anti-freezing error
four times Anti-high temperature protection
2 FLOW CHART OF TROUBLESHOOTING
Service personnel shall collect the malfunction information as much as possible and research them
thoroughly, list these electrical parts which may cause malfunction, service personnel shall be able to
GHWHUPLQHWKHVSHFL¿FUHDVRQDQGVROYHWKHIDXOWHGSDUWV
z
Observe the status of the complete device and do not observe the partial
z
,WLVDGYLVHGWRVWDUWIURPWKHVLPSOHRSHUDWLRQGXULQJDQDO\]LQJMXGJLQJDQGFRQ¿UPLQJPDOIXQFWLRQUHDVRQ
WKHQFRQGXFWWKHFRPSOLFDWHGRSHUDWLRQVVXFKUHPRYDORIGHYLFHSDUWUHSODFHPHQWDQGUHIULJHUDQW¿OOLQJ
z
Find the malfunction reason carefully as unit may occur several malfunction at the same time and one
malfunction may develop into several malfunction, so entire system analysis shall be established to make
the judged result exact and credible .

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GUHN09NK3AO and is the answer not in the manual?

Gree GUHN09NK3AO Specifications

General IconGeneral
RefrigerantR410A
Indoor Unit Weight8 kg
Cooling Capacity9000 BTU
Heating Capacity9000 BTU
Power Supply220V, 50Hz

Related product manuals