51
Installation and Maintenance
Service Manual
Wiring connection of controller
C
ompressor wire
U phase of blue wire for compressor
V phase of yellow wire for
compressor
W phase of red wire for compressor
(please refer to the top cover of
compressor)
Zero wire and live
wire, communication
wire
Brown live wire AC_L
Blue zero wire N
Black communication
wire COM-INTER
EMI ltering magnetic
ring(The zero wire
and live wire wind the
ring for 5 circles)
Ground lead
Yellow and green – E
Overload
Temperature
sensor
2-way valve
Electronic
expansion
valve
Outdoor fan
motor
4-way valve