33
Technical Information
Service Manual
Safety Precautions for Refrigerant
 
Appliance lled with ammable gas R32.
 
Before install and use the appliance, read the owner's 
manual rst.
 
 Before install the appliance, read the installation 
manual rst.
 Before repair the appliance, read the service manual 
rst.
● To realize the function of the air conditioner unit, a special 
refrigerant circulates in the  system.  The used refrigerant is 
the fluoride R32,which  is  specially cleaned. The refrigerant 
is  flammable  and  inodorous. Furthermore,  it  can  leads  to 
explosion under certain  conditions.  But the flammability of 
the refrigerant is very low. It can be ignited only by re.
● Compared to common  refrigerants,  R32 is a nonpolluting 
refrigerant with no harm to  the  ozonosphere. The influence 
upon the greenhouse effect is  also  lower. R32  has  got very 
good  thermodynamic  features  which lead  to a  really  high 
energy efciency. The units therefore need a less lling.
WARNING:
● Do not use means to accelerate the defrosting  process or 
to clean, other than those recommended by the manufacture.
Should repair be necessary,contact your nearest authorized 
Service Centre. Any repairs carried out by unqualied
personnel may be dangerous. The appliance shall be stored 
in a room  without  continuously operating ignition sources. 
(for example:open ames , an operating gas appliance or an 
operating electric heater.)
● Do not pierce or burn.
● Appliance shall be installed, operated and stored in a room 
with a oor area larger than Xm
2
.(Please refer to table "a" in 
section of "  Safety operation of flammable  refrigerant " for 
space X.)
● Appliance  filled  with  flammable  gas  R32.  For  repairs, 
strictly follow manufacturers instructions only.Be aware that 
refrigrants not contain odour.
● Read specialists manual.
 
This appliance is not intended for use by persons (including 
children)  with  reduced  physical,  sensory  or  mental 
capabilities,  or  lack  of  experience  and knowledge,  unless 
they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.
Children should  be supervised  to ensure  that  they  do  not 
play with the appliance.
1) Frequency band(s) in which the radio equipment operates: 
2400MHz-2483.5MHz
2)  Maximum  radio-frequency  power  transmitted  in  the 
frequency band(s)  in which  the  radio equipment  operates: 
20dBm
                               R32: 675
                               This marking indicates that this product
                                should not be disposed with other
                                house hold wastes. To prevent possible
                                harm to the environment or human
health  from  uncontrolled  waste  throughout  the  EU.  To 
prevent possible harm to the environment or human health.
From  uncontrolled  waste  disposal, recycle  it  responsibly 
to promote the  sustainable  reuse of material resources.  To 
return your used device, please use the return and collection 
systems  or  contact  the  retailer  where  the  product  was 
purchased.They can take this product for environmental safe 
recycling.
If it  needs to  install,  move or  maintain the  air conditioner, 
please contact dealer or local servicecenter to conduct it at 
rst. Air conditioner must be installed, moved or maintained 
by appointed unit. Otherwise, it may cause serious damage 
or personal injury or death.
Safety Operation of Flammable Refrigerant
Qualification  requirement  for  installation  and 
maintenance man
● All the  work  men  who  are  engaging  in  the refrigeration 
system should  bear the  valid certification  awarded by  the 
authoritative organization  and the qualification  for dealing 
with the refrigeration system recognized by this industry. If it 
needs other technician to maintain and repair the appliance, 
they  should  be  supervised  by  the  person  who  bears  the 
qualication for using the ammable refrigerant.
●It  can  only  be repaired  by  the  method  suggested by  the 
equipments manufacturer.
Installation notes
● The  air conditioner  is not  allowed to  use in  a room  that 
has running re (such as re source,working coal gas ware, 
operating heater).
● It is not allowed to drill hole or burn the connection pipe.
● The air conditioner must be installed in a room that is larger 
than the minimum room area.
The  minimum  room  area  is  shown  on  the  nameplate  or 
following table a.
● Leak test is a must after installation.