77
Installation and Maintenance
Service Manual
Step Procedure
7. Remove evaporator assy
a
Remove 2 screws xing evaporator assy.
At the back of the unit, Loosen the clasp of the
connection pipe clamp and then remove the connection
pipe clamp.
First remove the left side of evaporator from the groove
of bottom shell and then remove the right side from the
clasp on the bottom shell.
Adjust the position of connection pipe on evaporator
slightly and then lift the evaporator upwards to remove
it.
b
c
d
Clasp
Connection pipe
Screws
Connection pipe clamp