84
Installation and Maintenance
Service Manual
Step Procedure
4. Remove electric box assy
Remove the screws fixing the electricbox; loosen the
wire bundle; pull out the wiring terminals and then pull
electric boxupwards to remove it.
5. Remove axial ow blade
Remove nut fixing the blade and then remove the
blade.
6. Remove motor
Remove screws xing the motor and then remove the
motor.
screws
electric box
assy
axial ow
blade
nut
screws
motor