42
Removal Procedure
erudecorPspetS
Remove connection screws of evaporator
assy and motor clamp. Release clasps
connecting evaporator assy to rear case. Then 
remove evaporator assy.  
7. Remove electric box assy 
8.Remove evaporator 
Unplug indoor temp sensor. 
Remove connection screws of electric box
assy and rear case. Release clasps and 
remove connection screws of earthing wire 
and evaporator assy. Then remove electric
box assy.  
Turn over the rear case assy and remove
connecting pipe clamp. Release clasps 
between connecting pipe clamp and rear case
assy. Then remove connecting pipe clamp. 
2
1
1
2
Pipe Clamp 
Indoor Temp Sensor
Electric Box Cover
Electric Box Assy 
Auxiliary Piping
 Evaporator Assy