73
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Procedure
Step
1. Remove lter
2. Remove horizontal louver
a
b
Panel
Clasps
Left lter and right ler
Axile bush
Axile bush
Open the panel.
Loosen the clasp shown in the fig and
then pull the left filter and right filer
outwards to remove them.
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
Horizontal louver
Horizontal louver
Location of step motor
Location of step motor
09/12K
18/24K