After tighten the screw, pull the power cord slightly
to check if it is firm.
Never cut the power connection wire to prolong or
shorten the distance.
NOTICE
NOTICE
NOTICE
4.
2.
If the outdoor unit is higher than the wall hole,
1. Remove the wire clip; connect the power con-
Hex nut diameter
Tightening torque(N m)
.
The water outlet can't be placed in water in
order to drain smoothly.
The wiring board is for reference only, please refer
The drain hose can't be fluctuant
2.
9
The through-wal height of drain hose shoul
not be higher than the outlet pipe hole of in-
door unit.
Slant the drain hose slightly downwards.
The drain hose can't be curved, raised and
fluctuant, etc.
1/4''
3/8''
1/2''
5/8''
3/4''
15~20
30~40
45~55
60~65
70~75
Step 5:
Connect outdoor electric wire
the drain hose
can't raise
upwards.
The water outlet
can't be placed
in water
The drain hose
can't be fluctuant
The water
outlet can't be
Fix the power connection wire and signal con-
trol wire with wire clip (only for cooling and h-
eating unit).
fluctuant
Neaten the pipes
Step 6:
1.
nection wire and signal control wire (only for
cooling and heating unit) to the wiring terminal
according to the color; fix them with screws.
Tighten the union nut with torque wrench
by referring to the sheet below.
to the actual one.
reasonably and hidden possibly. Min. semidiam-
eter of bending the pipe is 10cm.
yellow-
green
The pipes should be placed along the wall, bent
you must set a U-shaped curve in the pipe
before pipe goes into the room, in order to
prevent rain from getting into the room.
N(1)
POWER
2
(black)
L(3)
brown
N
Indoor unit connection
L
blue
black
brown
blue
yellow-
green
wall
U-shaped curve
drain hose