Gree GWH09AGAXB-K6DNA1B/O - Installation of Outdoor Unit

Gree GWH09AGAXB-K6DNA1B/O
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
foot holes
foot holes
1. Remove the screw on the right handle of out-
(select it according to the actual inst-
Step 1:
Fix the support of outdoor unit
2.
gas valve
liquid pipe
gas pipe
liquid
valve
Step 4:
Connect indoor and outdoor pipes
allation situation)
1.
door unit and then remove the handle.
1.
union nut
pipe joint
Step 3:
Fix outdoor unit
NOTICE
2.
Step 2:
Install drain joint
(only for some models)
1. Connect the outdoor drain joint into the hole
NOTICE
Installation of outdoor unit
Select installation location according to
the house structure.
Fix the support of outdoor unit on the sele-
cted location with expansion screws.
on the chassis, as shown in the picture below.
NOTE
cross-hole
Connect the drain hose into the drain vent.
2.
3.
Remove the screw cap of valve and aim the
pipe joint at the bellmouth of pipe.
As for the shape of drainage joint, please refer
to the current product. Do not install the drainage
joint in the severe cold area. Otherwise,it will be
frosted and then cause malfunction.
Pretighten the union nut with hand.
When there're multiple cables
passing through it, the cross-hole
of handle should be knocked off
and eliminate the sharp burrs for
avoid damaging the cables.
Only applicable for some models.
at least 3cm above the floor
handle
screw
Take sufficient protective measures when installin g
the outdoor unit.
Make sure the support can withstand at least fou r
times of the unit weight.
The outdoor unit should be installed at least
3cm above the floor in order to install drain joint.
(for the model with heating tube, the installation
height should be no less than 20cm.)
For the unit with cooling capacity of 2300W
~
5000W,
6 expansion screws are needed ; for
the unit with cooling capacity of 6000W~8000W,
8 expansion screws are needed; for the unit
with cooling capacity
of 10000W~16000W, 10
expansion screws are needed.
drain vent
Drain hose
8
chassis
outdoor drain joint