99
Installation and Maintenance
Service Manual
No. Name No. Name
1 Indoor unit 8 Sealing gum
2 Outdoor unit 9 Wrapping tape
3 Connection pipe 10
Support of outdoor 
unit
4 Drainage pipe 11 Fixing screw
5
Wall-mounting 
frame
12
Drainage plug(cooling 
and heating unit)
6
Connecting 
cable(power cord)
13
Owners manual, 
remote controller
7 Wall pipe
8.2 Installation Parts-checking 
8.3 Selection of Installation Location
1.Please contact the local agent for installation.
2.Dont use unqualied power cord.
3. Outdoor Unit:
(1) Select a location where the noise and outow air emitted by 
the outdoor unit will not affect neighborhood.
(2) The location should be well ventilated and dry, in which 
the outdoor unit wont be exposed directly to sunlight or strong 
wind.
(3) The location should be able to withstand the weight of 
outdoor unit.
(4) Make sure that the installation follows the requirement of 
installation dimension diagram.
(5) Select a location which is out of reach for children and far 
away from animals or plants.If it is unavoidable, please add 
fence for safety purpose.
Note:
1. Safety Precaution
(1) Must follow the electric safety regulations when installing 
the unit.
(2) According to the local safety regulations, use qualified 
power supply circuit and air switch.
(3) Make sure the power supply matches with the requirement 
of air conditioner. Unstable power supply or incorrect wiring 
may result in electric shock,re hazard or malfunction. Please 
install proper power supply cables before using the air 
conditioner.
(4) Properly connect the live wire, neutral wire and grounding 
wire of power socket.
(5) Be sure to cut off the power supply before proceeding any 
work related to electricity and safety.
(6) Do not put through the power before nishing installation.
(7) If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualied persons in 
order to avoid a hazard.
(8) The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper tube.
(9) The appliance shall be installed in accordance with national 
wiring regulations.
(10) Appliance shall be installed, operated and stored in a 
room with a oor area larger than “X”m  (see table a).
8.4 Requirements for electric connection
Air-conditioner Air switch capacity
09K 10A
12/18/24K  16A
2. Grounding Requirement:
(1) The air  conditioner  is rst class electric appliance. It must 
be properly grounding with specialized grounding device 
by a professional. Please make sure it is always grounded 
effectively, otherwise it may cause electric shock.
(2) The yellow-green wire in air conditioner is grounding wire, 
which cant be used for other purposes.
(3) The grounding resistance should comply with national 
electric safety regulations.
(4) The appliance must be positioned so that the plug is 
accessible.
(5) An all-pole disconnection switch having a contact separation 
of at least 3mm in all poles should be connected in xed wiring.
(6) Including an air switch with suitable capacity, please note    
the following table. Air switch should be included magnet 
buckle and heating buckle function, it can protect the circuit-
short and overload. (Caution: please do not use the fuse only 
for protect the circuit)
Please notice that the unit is filled with 
ammable gas R32. Inappropriate treatment of 
the unit involves the risk of severe damages of 
people and material. Details to this refrigerant 
are found in chapter “refrigerant”.
2. Indoor Unit:
(1) There should be no obstruction near air inlet and air outlet.
(2) Select a location where the condensation water can be 
dispersed easily andwont affect other people.
(3) Select a location which is convenient to connect the 
outdoor unit and near the power socket.
(4) Select a location which is out of reach for children.
(5) 
The location should be able to withstand
 the weight of 
indoor unit and wont increase noise and vibration.
(6) 
The appliance must be installed 2.5m above oor.
(7) Dont install the indoor unit right above the electric 
appliance.
(8) Please try your best to keep way from uorescent lamp.
1. Basic Requirement:
Installing the unit in the following places may cause 
malfunction. If it is unavoidable, please consult the local dealer:
(1) The place  with  strong heat sources, vapors, ammable or 
explosive gas, or volatile objects spread in the air.
(2) The place with high-frequency devices (such as welding 
machine, medical equipment).
(3) The place near coast area.
(4) The place with oil or fumes in the air. 
(5) The place with sulfureted gas.
(6) Other places with special circumstances.
(7) The appliance shall nost be installed in the laundry.
(8) Its not allowed to be installed on the unstable or motive 
base structure(such as truck) or in the corrosive environment 
(such as chemical factory).