108
Installation and Maintenance
Service Manual
Remove screws fixing electric box assy and
mid-isolation board, loosen the bonding tie, pull off the
wiring terminal, lift to remove the electric box assy.
9. Remove electric box assy
10. Remove four-way valve assy
11. Remove electron expansion valve
electric boxassy
cover
electric box
four-way valve ass
electron expansion valve
y
We
Unsolder the spot weld of discharge and inhalation
tube sub-assy, electronic expansion valve,compressor
and condenser, and then remove the discharge and
inhalation tube sub-assy and electronic expansion valve.
lding cut the spot weld of four-way valve assy,
compressor air suction/discharging valve and
condenser pipe outlet, lift to remove the four-way valve
assy. (Note: release the refrigerant before welding
cutting.)