122
13. Remove 4-way valve assembly
Properly remove refrigerant charge, then remove valve by heating
brazed joints and withdrawing pipe from valve.
14. Remove compressor
Remove the three screws holding the compressor.
15. Remove valve assemblies and condensor
Remove the screws holding the condenser assembly, then remove
the screws holding the two valve assemblies.
4-way valve
Compressor
Condenser assy.
Small valve
Large valve
Disassembly of Outdoor Unit, continued
9,000 & 12,000 btuh Warning - Wait 10 minutes a er power is disconnected before starting disassembly.