10.2 Removal Procedure of Outdoor Unit (18K Unit)
Warning Be sure to wait 10 minutes or more after turning
off all power supplies before disassembling work.
Removal Procedure
Twist off the fastening screw used for fixing the handle,
pull it downward and then remove the handle.
Twist off the screws around the top cover, pull it
upward and then remove the top cover.
1. top cover
2. grille and right side plate
Twist off the screw around the grille and then remove
the grille.
Twist off the screws between right side plate and end
plate of condenser, valve support, pull it upward and
then remove the right side plate.
3. electric box
Disassemble the screws on electric box cover, pull out
the temperature sensor and then remove the electric
box.
Top cover
Screw
handle
screw
Temperature sensor
Ensure don not contact control panel when removing
electric box cover, if not, electrolytic capacity will discharge
and lead electric shock or burn out control panel.
Remove
Remove
Remove
58