94
Installation and Maintenance
Service Manual
Procedure
Step
Screws
Screws
Condenser
Remove 3 foot nuts on compressor, and then 
remove the compressor.
Note:
Protect the ports of discharge pipe and 
suction pipe to avoid foreign objects to 
enter it.
Remove the screws xing right side plate 
and then remove the left side plate.
Remove one screw xing the condenser, 
then remove the condenser.
Foot nuts
Compressor
16. Remove compressor
17. Remove left side plate
18. Remove condenser
Left side plate