104
Service Manual
Installation and Maintenance
8. Remove evaporator sub-assy
Remove the screws fixing connection
pipe clamp, to remove the connection
pipe clamp.
pipe clamp
evaporator sub-assy
water tray
Loosen the clasps connecting the water
tray and chassis, and then remove the
water tray.
Remove the screws fixing evaporator
sub-assy, slightly regulate the tube, to
remove the evaporator sub-assy.
screw