6
Technical Information
Service Manual
Capacity ratio(%)
Outdoor Temp.(°C)
0
20
40
60
80
100
120
31 33 35 37 39 41 43 45 47
• Conditions
Indoor: DB27°C/WB19°C
Indoor air flow:Super High
Pipe length: 5m
Capacity ratio(%)
Outdoor Temp.(°C)
20
40
60
80
100
120
-20-15 -10-5
051
0
• Conditions
Indoor: DB20°C/WB15°C
Indoor air flow:Super High
Pipe length: 5m
Capacity ratio(%)
–15 –10 –5
110
100
90
80
70
60
50
40
075 10
Outdoor temp.(°C)
Conditions
Indoor:DB20°C/WB15°C
Indoor air flow:Super High
Pipe length:5m
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Cooling: Heating:
Current(A)
Compressor Speed (rps)
12010080604020
Compressor Speed (rps)
Current(A)
13
11
9
7
5
3
1
120
10080604020
13
11
9
7
5
3
1
• Conditions
Indoor: DB27°C/WB19°C
Outdoor: DB35°C/WB24°C
Indoor air flow: High
Pipe length: 5m
• Conditions
Indoor: DB20°C/WB15°C
Outdoor: DB7°C/WB6°C
Indoor air flow: High
Pipe length: 5m
230V
230V
Cooling:
Heating: