112
Installation and Maintenance
Service Manual
Step Procedure
10. Remove vertical louver
Remove 3 screws xing evaporator assy. Adjust the
position of connection pipe on evaporator slightly
and then lift the evaporator upwards to remove it.
11. Remove motor press plate
Remove the screws fixing motor clamp and then
remove the motor clamp.
12. Remove motor and cross ow fan
Remove the screws at the connection place of
cross ow fan and motor; lift the motor and cross
ow fan upwards to remove them.
Screws
Screws
Screw
Screw
Motor