104
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant 
completely before removal.
Step Procedure
    Before disassemble
Turn off the air conditioner and disconnect the
power before disassemble the air conditioner.
    1. Remove lter
Hold the handle on the lter, pull it upwards to let
the clasp at the top part of the lter loose, push it
forwards and then the lter can be pulled out.
 
2.Remove upper and lower guide louver
Push out the plug pin on upper and lower guide 
louver, Bend the guide louver with hand and then 
separate the guide louver from the crank shaft of 
step motor to remove it.
Guide Louver
Filter
Handle