53
Installation and Maintenance
Service Manual
1. Select the installation location according to the require-
ment of this manual.(See the requirements in installation 
part)
2. Handle unit transportation with care; the unit should not 
be carried by only one person if it is more than 20kg.
3. When installing the  indoor  unit  and outdoor unit, a  suf-
cient xing bolt must be installed; make sure the installation 
support is rm.
4. Ware safety belt if the height of working is above 2m.
5. Use equipped components or appointed components dur-
ing installation.
6. Make sure no foreign objects are  left in the unit after n-
ishing installation.
Electrical Safety Precautions:
7. Notes for Installation and Maintenance
Safety Precautions: 
Important!
Please read the safety precautions carefully before 
installation and maintenance.
The following contents are very important for installation 
and maintenance.
Please follow the instructions below.
●The installation or maintenance must accord with the 
instructions.
●Comply with all national electrical codes and local 
electrical codes.
●Pay attention to the warnings and cautions in this 
manual.
●All installation and maintenance shall be performed by 
distributor or qualied person.
●All electric work must be performed by a licensed 
technician according to local regulations and the 
instructions given in this manual.
●Be caution during installation and maintenance. Prohibit 
incorrect operation to prevent electric shock, casualty and 
other accidents.
1. Cut off the power supply of air conditioner before 
checking and maintenance.
2. The air condition must apply specialized circuit and 
prohibit share the same circuit with other appliances.
3. The air conditioner should be installed in suitable 
location and ensure the power plug is touchable.
4. Make sure each wiring terminal is connected rmly 
during installation and maintenance.
5. Have the unit adequately grounded. The grounding 
wire can't be used for other purposes.
6. Must apply protective accessories such as protective 
boards, cable-cross loop and wire clip.
7. The live wire, neutral wire and grounding wire of 
power supply must be corresponding to the live wire, 
neutral wire and grounding wire of the air conditioner.  
8. The power cord and power connection wires can't be 
pressed by hard objects.
9. If power cord or connection wire is broken, it must be 
replaced by a qualied person.
When refrigerant leaks or requires discharge during 
installation, maintenance, or disassembly, it should 
be handled by certied professionals or otherwise in 
compliance with local laws and regulations.
1. Avoid contact between refrigerant and re as it generates 
poisonous gas; Prohibit prolong the connection pipe by 
welding.
2. Apply specied refrigerant only. Never have it mixed with 
any other refrigerant. Never have air remain in the refrigerant 
line as it may lead to rupture or other hazards.
3. Make sure no refrigerant gas is leaking out when 
installation is completed.
4. If there is refrigerant leakage, please take sufcient 
measure to minimize the density of refrigerant.
5. Never touch the refrigerant piping or compressor without 
wearing glove to avoid scald or frostbite.
Warnings
Refrigerant Safety Precautions:
Improper installation may lead to re hazard, explosion, 
electric shock or injury.
Installation Safety Precautions:
Part 
Ⅱ
: Installation and Maintenance 
10. If the power cord or connection wire is not long enough, 
please get the specialized power cord or connection wire 
from the manufacture or distributor. Prohibit prolong the wire 
by yourself.
11. For the air conditioner without plug, an air switch must 
be installed in the circuit. The air switch should be all-pole 
parting and the contact parting distance should be more than 
3mm.
12. Make sure all wires and pipes are connected properly and 
the valves are opened before energizing.
13. Check if there is electric leakage on the unit body. If yes, 
please eliminate the electric leakage.
14. Replace the fuse with a new one of the same specication 
if it is burnt down; dont replace it with a cooper wire or 
conducting wire.
15. If the unit is to be installed in a humid place, the circuit 
breaker must be installed.