Technical Information
Service Manual
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
 
Connection pipe length: 5 m.
Heating:
Rated cooling 
condition(°C) (DB/WB)
Model 
Pressure of gas pipe 
connecting indoor and 
outdoor unit 
Inlet and outlet pipe 
temperature of heat 
exchanger
Fan speed of 
indoor unit
Fan speed of 
outdoor unit 
Indoor Outdoor  P (MPa)  T1 (°C) T2 (°C)
20/- 7/6
09K
2.8~3.2
35 to 63 2 to 5
TURBO High
12K 35 to 65 2 to 5
18K 2.2~2.4 70 to 40 1 to 5
24K 2.2 t~ 2.4 70 to 40 1 to 5
Cooling:
Heating: