Household (Townhouse) Central Air Conditioning Unit
4
Selection of power supply wiring and air switch:
Model Power supply type air switch
(
A
)
power supply cord
HLR45SNa-M 3Ph 63 H07RN-F 5G10.0mm
2
HLR35SNa-M 3Ph 50 H07RN-F 5G6.0mm
2
HLR25SNa-M 3Ph 32
H07RN-F 5G4.0mm
2
HLR22SNa-M 3Ph 25
Note
:
① .
The power supply wire must be copper core wire, and the working temperature can not be higher
than limited value.
② .
If the length of power supply wire is longer than 15meters, do please increase the section area to
avoid any accident due to over-load.
③ .
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualied person in order to avoid a hazard.
④ .
The appliance shall be installed according to national regulations.
⑤ .
When installing the connection wiring for manual controller, the wire must be put inside a separate
protective sheath to avoid direct sunshine.
4. Operation Instructions of Controller
4.1 Display function on display board
17
16
15
13
12
11
14
OFF
ON
EXIT
MODE
CHECK
PARAMETER SET PASSWORD
DEFROST ABC TEST
4.2 LCD displaying panel
1) HEAT: It displays when unit is heating, otherwise it would not display.
2) ERROR CODE: It shows the error code displayed on Main Display Area. It displays when there is