EasyManua.ls Logo

Gree HLR45SNa-M - Water Pipe Connection

Gree HLR45SNa-M
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Household (Townhouse) Central Air Conditioning Unit
13
Electric wiring diagram for no connection control between fan coil and host
M
M
M
M
M
M
Fan coil
Fan coil
Fan coil
Electric
valve
Electric
valve
Electric
valve
N
L
E
Temperature
control
Temperature
control
Temperature
control
Electric wiring diagram for connected control between fan coil and host Special notice:
M
M
X2
X3
X4
M
M
M
M
Fan coil
Fan coil Fan coil
Electric
valve
Electric
valve
Electric
valve
N
L
E
Temperature
control
Temperature
control
Temperature
control
1) When connected the control wire between fan coil and host, connect the live wire of fan coil controller
to the port X2~X7 on terminal switch board inside electric case through the switch of temperature control;
Meanwhile, disconnect the original connecting wire between main controller and end-switch . Then connect
the port X1 at switch board to end-switch at main board of indoor unit.
2) When connect control is not conducted between fan coil and host, please connect the end-switch at
main board with live wire (short connected when outgoing).it shall be done by professional.
3) Method of shutting off the power is cutting off the air switch. Contact distance between the electrodes
of the air switch must be beyond 3mm.
4) Installation should conform to the local electric standard.
5) The appliance shall be installed in accordance with national wiring regulations.
6) Before obtaining access to terminals, all supply circuits must be disconnected.
7) If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualied person in order to avoid a hazard. 8
An all-pole disconnection switch having a contact separation of
at least 3mm in all poles should be connected in xed wiring. 9
The appliance shall not be used by children
without supervisor.
8.3 Water Pipe Connection
When connecting water pipe, please screw off the plug at water in pipe and water out pipe, connect
the water-in hose and water-out hose separately with the water-in pipe and water-out pipe of the unit.
Please note the following points when constructing:
1) Water connect pipes must be new, do not use old pipes instead of new ones.