Loading...
91
Test Operation, Troubleshooting and Maintenance
Replacement of the compressor
Note: be sure there is no refrigerant inside the system and power supply has been cut off before
replacement.
Steps Image Instructions
1. Remove the front
panels.
Remove screws at the front panel.
Loosened screws should be put
together to avoid loss.
Pull the front panel upwards and
then remove it.
Properly keep the removed front
panel to avoid from being damaged.
2. Remove power
lines and the
electric heater.
Loosen screws of power lines with a
screwdriver.
Draw out power lines.
Draw out the electric heater.
Note that power lines and their
terminals should be numbered to
avoid incorrect rewiring.
3. Disconnect
power lines to the
compressor.
Desolder pipes quick to avoid
deformation.
Keep the replaced compressor
complete for further analysis.