REFRIGERATION& PIPING SPECIFICATIONS
REFRIGERANT CHARGE
Model Number
Refrigerant
Type
Factory System
Charge (oz.)
Max Total Pipe
Length Without Adding
Refrigerant (ft.)
Additional
Charge Level
(oz./ft.)
NEO09HP115V1AO
R-410A
41.2
25
0.2
NEO12HP115V1AO
R-410A
45.9
25
0.2
NEO09HP230V1AO
R-410A
45.9
25
0.2
NEO12HP230V1AO
R-410A
45.9
25
0.2
NEO18HP230V1AO
R-410A
49.4
25
0.2
NEO24HP230V1AO
R-410A
56.4
25 0.5
NEO30HP230V1AO
R-410A
84.7
25
0.5
NEO36HP230V1AO
R-410A
91.7
25 0.5
REFRIGERANT PIPING LENGTHS
Model Number
Min. Pipe Length
for System (ft.)
Max Pipe Length for
System (ft.)
Max Elevation between
Outdoor & Indoor Units (ft.)
NEO09HP115V1AO
10
50
33
NEO12HP115V1AO
10
66
33
NEO09HP230V1AO
10
50
33
NEO12HP230V1AO
10
66
33
NEO18HP230V1AO
10
82
33
NEO24HP230V1AO
10
82
33
NEO30HP230V1AO
10
100
33
NEO36HP230V1AO
10
100
33
11
© 2014 Gree Electric Appliance, Inc.

Other manuals for Gree NEO09HP115V1A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree NEO09HP115V1A and is the answer not in the manual?

Gree NEO09HP115V1A Specifications

General IconGeneral
BrandGree
ModelNEO09HP115V1A
CategoryAir Conditioner
LanguageEnglish

Related product manuals