38
Installation and Maintenance
Service Manual
7DNHVXIILFLHQWSURWHFWLYHPHDVXUHVZKHQLQVWDOOLQJWKH
RXWGRRUXQLW
0DNHVXUHWKHVXSSRUWFDQZLWKVWDQGDWOHDVWIRXUWLPHVWKH
XQLWZHLJKW
7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVWLQFK
DERYHWKHÀRRULQRUGHUWRLQVWDOOGUDLQMRLQW$VVKRZLQ)LJ
)RU WKHXQLWZLWKFRROLQJFDSDFLW\RI:a:
H[SDQVLRQVFUHZVDUHQHHGHGIRUWKHXQLWZLWKFRROLQJFDSDFLW\
RI:a: H[SDQVLRQVFUHZVDUHQHHGHGIRUWKH
XQLWZLWK FRROLQJFDSDFLW\RI:a:H[SDQVLRQ
screws are needed.
$IWHUWLJKWHQLQJWKHVFUHZSXOOWKHSRZHUFRUGVOLJKWO\WR
FKHFNLILWLV¿UP
1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQ
WKHGLVWDQFH
7KHWKURXJKZDOOKHLJKWRIGUDLQKRVHVKRXOGQWEHKLJKHU
WKDQWKHRXWOHWSLSHKROHRILQGRRUXQLW$VVKRZLQ)LJ
6ODQW WKHGUDLQKRVHVOLJKWO\GRZQZDUGV7KHGUDLQKRVH
FDQWEHFXUYHGUDLVHGDQGÀXFWXDQWHWF$VVKRZLQ)LJ
Note:
Note:
Note:
The drain hos
can't raise
upwards
gas pipe
Liquid pipe
Liquid
valve
gas valve
Union nut
Pipe joint
Foot holes
Foot holes
8.6 Installation of Outdoor Unit
1. Fix the Support of Outdoor Unit(Select it according to
the actual installation situation)
6HOHFWLQVWDOODWLRQORFDWLRQDFFRUGLQJWRWKHKRXVHVWUXFWXUH

)L[WKHVXSSRUWRIRXWGRRUXQLWRQWKHVHOHFWHGORFDWLRQZLWK
expansion screws.
5. Connect Outdoor Electric W
ire
5HPRYHWKHZLUHFOLSFRQQHFWWKHSRZHUFRQQHFWLRQZLUH
DQGSRZHUFRUGWRWKHZLULQJWHUPLQDO¿[WKHPZLWKVFUHZV$V
VKRZLQ)LJ
6. Neaten the Pipes

7KHSLSHVVKRXOGEHSODFHGDORQJWKHZDOOEHQWUHDVRQDEO\
DQGKLGGHQ SRVVLEO\0LQVHPLGLDPHWHURIEHQGLQJWKHSLSHLV
10cm.
,IWKHRXWGRRUXQLWLVKLJKHUWKDQWKHZDOOKROH\RXPXVWVHW
D8VKDSHGFXUYHLQWKHSLSHEHIRUHSLSHJRHVLQWRWKHURRP
LQRUGHU WRSUHYHQWUDLQIURPJHWWLQJLQWRWKHURRP$V VKRZLQ
)LJ
)L[WKHPZLUHZLWKZLUHFOLS
2. Install Drain Joint(only for cooling and heating unit)
&RQQHFWWKHRXWGRRUGUDLQMRLQWLQWRWKHKROHRQWKHFKDVVLV
&RQQHFWWKHGUDLQKRVHLQWRWKHGUDLQYHQW
$VVKRZLQ)LJ
3. Fix Outdoor Unit
3ODFHWKHRXWGRRUXQLWRQWKHVXSSRUW
)L[WKHIRRWKROHVRIRXWGRRUXQLWZLWKEROWV
$VVKRZLQ)LJ
4. Connect Indoor and Outdoor Pipes

5HPRYHWKHVFUHZRQWKHULJKWKDQGOHDQGYDOYHFRYHURI
RXWGRRUXQLWDQGWKHQUHPRYHWKHKDQGOHDQGYDOYHFRYHU$V
VKRZLQ)LJ
5HPRYHWKHVFUHZFDSRIYDOYHDQGDLPWKHSLSHMRLQWDWWKH
EHOOPRXWKRISLSH$VVKRZLQ)LJ
3UHWLJKWHQLQJWKHXQLRQQXWZLWKKDQG
7LJKWHQWKHXQLRQQXWZLWKWRUTXHZUHQFK
+H[QXWGLDPHWHULQFK 7LJKWHQLQJWRUTXHIW·Ibf)
ĭ 11.10~14.75
ĭ 22.82~29.50
ĭ 33.19~40.56
ĭ 44.24~47.94
ĭ 51.32~55.31
5HIHUWRWKHIROORZLQJWDEOHIRUZUHQFKPRPHQWRIIRUFH
:
)LJ )LJ
)LJ
)LJ
)LJ
)LJ
)LJ
)LJ
U-shaped curve
Wall
Drain hose
At least 1 1/6 inch above the floor
Chassis
Outdoor drain joint
Drain hose
Drain vent
Handle
N(1) 2 3
2
3
N(1) L2
G
L1
L2
L1
intdoor unit connection
KDQGOH
YDOYHFRYHU