EasyManua.ls Logo

Green GT790 - Technical Specification

Green GT790
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1716
Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059
Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051
Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059
Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051
TECHNICAL
SPECIFICATION
INTERNAL BOARD
ERROR CODE
(EVAPORATOR UNIT)
In case the following codes appear at the
display during air-conditioning usage,
it might indicate expressive failures to/
with the product. For correction, follow
as below:
- Reduce air-conditioning speed and turn
it off, after approximately 10 minutes,
restart the air-conditioning system. In
case the code persists, turn off the system
and contact specialized assistance. (If
the code disappears, you can continue
using it).
Error Codes:
-
E01 Tension/battery is low;
-
E02 A probable bad connection of the
Blower Motor – check cables, connec-
tors or need of replacing the Blower
Motor;
-
H22 Inlet sensor failure, which indicates
the mode might alter after returning to
normal function;
-
H23 Outlet sensor failure, which indi-
cates the mode might alter after return-
ing to normal function;
-
E04 Temperature sensor of the pipe
(Air-Outlet);
-
E05 Compressor is overheating and
as soon as the Compressor´s temper-
ature goes down; it returns to normal
function;
-
E06 Check if the circuit, coming from
the Compressor in direction to the Con-
denser Fan, is open;
-
E07 Check for a possible short circuit
between the Compressor and Condens-
er Fan;
-
E09 Defect at the command board of
the Condenser Fan – Board must be
replaced;
-
E10 Replace the Condenser Fan;
-
E11 Check a possible damage caused to
the cables connecting the Compressor
to the Condenser Fan.
3. 4.
ADVICE: IF THE ALERT CODE THAT APPEARS AT THE COMPRESSOR´S FAILURE
INDICATOR DOES NOT CORRRESPOND TO THE CODES AS DESCRIBED AT THE TABLE
ABOVE, THE COMPRESSOR´S CONTROLLING PANEL MUST BE REPLACED
MODEL DS630051 DS540059
Nominal tension (V) 12 24
Current (A) 60-80 15-45
Power (W) 960 950
Refrigerating capacity (W) 1000 - 3000
Performance coefficient ≥ 2,5
Refrigerant R134a
Oil ISO VG 68
Refrigerant quantity (g) 600
Speed (RPM) 1000 - 3000
Internal dimension
(Evaporator Unit) (mm)
460 X 160 X 320
External dimension
(Condenser Unit) (mm)
660 X 490 X 210
Power cable specification 3.0m x 8mm