5878 • 5880 • 5882
15
Typical Measurements (contd)
Continuity Check
1. Set the selector to the 20 position.
2. Connect the test leads across the device to be tested.
3. The display indicates the resistance of the circuit or component, or OL if the resistance is
greater than 20 . The internal fuse is automatically tested during the continuity check.
Models 5880 and 5882 only:
To improve the accuracy of the continuity measurement, compensate for the resistance of the
test leads as follows:
1. Connect the test leads together.
2. Press and hold until / appears on the display. This procedure will subtract the
lead resistance from the continuity measurement.
3. To cancel this compensation, press and hold until / disappears from the display.