13
WARNING
Disconnect air compressor from power source and bleed off all air pressure before attempting
any maintenance or repair.
SHUTDOWN AND STORAGE:
MAINTENANCE
1. Turn the switch to the OFF position
2. Turn the pressure regulator knob fully counterclockwise to close airow from air outlet port.
Check the outlet pressure gauge to ensure that it reads 0 PSI.
3. Remove the air hose and any air accessories.
4. Drain moisture from the air tank by slowly opening the air tank drain valve by turning counter
clockwise. Tilt tank to remove all moisture. Once all the moisture has drained out, close the
tting securely.
5. Allow the compressor to cool down.
6. Wipe the air compressor clean and store it in a clean, dry, and non-freezing location.
WHEN PERFORMING ANY MAINTENANCE OR SERVICE:
1. The air compressor must be turned off.
2. Open tank drain to bleed off all air pressure before attempting any maintenance or repair.
3. Allow compressor to fully cool before attempting any maintenance or repair.
Check the air compressor frequently for any visible problems and follow maintenance
procedures each time the compressor is used.
MAINTENANCE CHECKLIST:
Daily:
• Drain accumulated liquid from tank.
• Check for unusual noise and/or vibrations.
• Check that all fasteners are secure.
• Wipe compressor clean.
Monthly:
• Check for air leaks.