WARNING
Avoid the intake of large objects that could damage the
impeller.
13 TRANSPORTATION AND
STORAGE
WARNING
Remove the battery pack from the machine before
tranportation and storage.
13.1 MOVE THE MACHINE
Only hold the machine with the handgrip.
13.2 STORE THE MACHINE
Clean the machine before storage.
Make sure that the motor is not hot when you store the
machine.
Make sure that the machine does not have loose or
damaged parts. If it is necessary, do these steps/
instructions:
Replace the damaged parts.
Tighten the bolts.
Speak to a person of an approved service center.
Store the machine in a dry area.
Make sure that children cannot come near the machine.
14 TROUBLESHOOTING
PROBLEM POSSIBLE
CAUSE
SOLUTION
The machine
does not
blow or
mulch.
The tube has block-
ages.
Make sure that the
tube is clear.
The impeller has
blockages.
Make sure that the im-
pller is clear.
The bag is full. Empty the bag.
The bag is dirty. Clean the bag.
The bag has dam-
age.
Replace the bag.
The bag is unzip-
ped.
Lock the bag.
The battery pack is
not secure.
Make sure that you
latch the battery pack
correctly.
The battery capaci-
ty is low.
Charge the battery
pack.
PROBLEM POSSIBLE
CAUSE
SOLUTION
The machine
does not start.
The on/off button is
in the OFF position.
Push the on/off button.
The on/off button is
defective.
Replace the defective
parts by an approved
service centre.
The tube is not in-
stalled correctly.
Make sure that you in-
stall the tube correctly.
The gate is not
locked.
Make sure that you
lock the gate.
The battery pack is
not secure.
Make sure that you
latch the battery pack
correctly.
The battery capaci-
ty is low.
Charge the battery
pack.
15 TECHNICAL DATA
Voltage 40 V
Air volume 340 CFM
Air speed 185 MPH (298 Km/h)
Weight (without
battery pack)
9.92 lbs. (4.5 kg)
Battery model 29472 and other BAF series
Charger model 29482 and other CAF series
The recommended ambient temperature range:
Item
Temperature
Blower storage temperature
range
32°F (0°C) - 113°F (45°C)
Blower operation tempera-
ture range
32°F (0°C) - 113°F (45°C)
Battery charging temperature
range
39°F (4°C) - 104°F (40°C)
Charger operation tempera-
ture range
39°F (4°C) - 104°F (40°C)
Battery storage temperature
range
32°F (0°C) - 113°F (45°C)
Battery discharging tempera-
ture range
32°F (0°C) - 113°F (45°C)
10