Justin GuerraSep 7, 2025
What to do if Groen TDH-CE Mark is hard to tilt?
- AAllison HarrisSep 7, 2025
If your Groen Kettle is hard to tilt, inspect the gears for any foreign materials and ensure they are properly lubricated.
What to do if Groen TDH-CE Mark is hard to tilt?
If your Groen Kettle is hard to tilt, inspect the gears for any foreign materials and ensure they are properly lubricated.
What to do if the safety valve pops on Groen TDH-CE Mark Kettle?
If the safety valve on your Groen Kettle pops, consider the following: * Check for air in the jacket. * Inspect the safety valve. If it pops at pressures below 49 PSIG, replace it. * Verify if the high limit pressure switch is set too high. * Examine the thermostat operation.
What to do if the pilot lights, but the main burner will not come on, and the spark stays on, in Groen TDH-CE Mark Kettle?
If the pilot light is on, but the main burner won't ignite and the spark remains on in your Groen Kettle, check these items: * Ensure the sensor cable is securely attached to terminal '1' on the module and to the sensor. * Inspect the sensor ceramic for cracks. * Confirm that the cable is not grounded out; correct any grounding issues. * Check the sensor cable for continuity and the condition of its insulation. * Verify the gas pressure. * Clean the pilot assembly. * Tighten all mechanical and electrical connections.
What to do if the pilot lights, but the main burner will not come on, and spark does not stay on in Groen TDH-CE Mark?
If the pilot light ignites, but the main burner doesn't come on and the spark does not stay on in your Groen Kettle, check that the gas pressure meets the control manufacturer’s specifications. If the issue persists, replace the spark ignition module.
What to do if the main burner comes on but will not stay lit on Groen TDH-CE Mark?
If the main burner of your Groen Kettle comes on but won't stay lit, check the burner ground for a bad wire or connection, replacing it with high-temperature wire if needed. Also, check for low gas supply pressure and consider replacing the ignition control module if necessary. Finally, inspect the ceramic insulator or pilot flame sensor for cracks and replace the flame sensor if it is cracked.
Why Groen TDH-CE Mark system does not produce a spark?
If your Groen Kettle system isn't producing a spark, here's what to check: * Examine the thermostat and close the contacts if they are open. * Check the AC voltage between terminals '1' and GND. If it’s not 230 VAC, check the high limit switch to ensure it is closed. * Inspect the pilot spark gap and regap it if it is not 7/64 inch (2.78 mm). * Look for cracks or breaks in the electrode ceramic. * Ensure the high tension cable is firmly attached and in good condition; replace the pilot if the cable is cracked or brittle. * If none of the above steps work, replace the electronic spark ignition module.
What to do if Groen TDH-CE Mark Kettle pilot lights but main burner will not come on and the spark stays on?
If the pilot light on your Groen Kettle lights, but the main burner won't come on and the spark stays on, check for a bad burner ground. Repair with high-temperature wire if necessary.
Why does Groen TDH-CE Mark Kettle continue heating after reaching desired temperature?
If your Groen Kettle continues heating after reaching the desired temperature, check the Temperature Controller dial setting.
How to fix Groen Kettle burners that will not light?
If the burners on your Groen Kettle won't light, ensure that the main gas supply valve is open. The handle should be in line with the gas pipe.
Why is my Groen TDH-CE Mark heating slowly?
If your Groen Kettle is heating slowly, check for air in the jacket.