EasyManua.ls Logo

Grow GM67 - Page 64

Grow GM67
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.hzgrow.com
57
Table 6-2
Parameter Name
Serial Instructions
Default Configuration
Factory Default Configuration:08 C6 04
08 00 F2 FF 00 FD 35
Scanning duration
4s:07 C6 04 08 00 88 28 FE 77
10s:07 C6 04 08 00 88 64 FE 3B
Single Scan Time(Scanning
duration)Quickly Set Up
Infinite:08 C6 04 08 00 F2 FA 00 FD 3A
3s:08 C6 04 08 00 F2 FA 03 FD 37
5s:08 C6 04 08 00 F2 FA 05 FD 35
10s:08 C6 04 08 00 F2 FA 0A FD 30
15s:08 C6 04 08 00 F2 FA 0B FD 2F
20s:08 C6 04 08 00 F2 FA 0C FD 2E
30s:08 C6 04 08 00 F2 FA 0D FD 2D
60s:08 C6 04 08 00 F2 FA 0E FD 2C
Trigger Mode
Button Holding:07 C6 04 08 00 8A 00
FE 9D
Button Trigger:07 C6 04 08 00 8A 02
FE 9B
Continuous scanning:07 C6 04 08 00
8A 04 FE 99
Automatic Induction: 07 C6 04 08 00 8A
09 FE 94
Host:07 C6 04 08 00 8A 08 FE 95
Break Time Settlement
0s:07 C6 04 08 00 89 00 FE 9E
0.5s: 07 C6 04 08 00 89 05 FE 99
3s:07 C6 04 08 00 89 1E FE 80
Buzzer Voice
Low:07 C6 04 08 00 8C 02 FE 99
Middle: 07 C6 04 08 00 8C 01 FE 9A
High: 07 C6 04 08 00 8C 00 FE 9B
Buzzer Type
*Passive Buzzer: 08 C6 04 08 00 F2 D8
00 FD 5C
Active Buzzer: 08 C6 04 08 00 F2 D8
01 FD 5B