57
Table 6-2
Parameter Name
Serial Instructions
Default Configuration
Factory Default Configuration:08 C6 04
08 00 F2 FF 00 FD 35
Scanning duration
4s07 C6 04 08 00 88 28 FE 77
10s:07 C6 04 08 00 88 64 FE 3B
Single Scan Time(Scanning
duration)Quickly Set Up
Infinite08 C6 04 08 00 F2 FA 00 FD 3A
3s08 C6 04 08 00 F2 FA 03 FD 37
5s08 C6 04 08 00 F2 FA 05 FD 35
10s08 C6 04 08 00 F2 FA 0A FD 30
15s08 C6 04 08 00 F2 FA 0B FD 2F
20s08 C6 04 08 00 F2 FA 0C FD 2E
30s08 C6 04 08 00 F2 FA 0D FD 2D
60s08 C6 04 08 00 F2 FA 0E FD 2C
Trigger Mode
Button Holding07 C6 04 08 00 8A 00
FE 9D
Button Trigger07 C6 04 08 00 8A 02
FE 9B
Continuous scanning07 C6 04 08 00
8A 04 FE 99
Automatic Induction: 07 C6 04 08 00 8A
09 FE 94
Host07 C6 04 08 00 8A 08 FE 95
Break Time Settlement
0s:07 C6 04 08 00 89 00 FE 9E
0.5s: 07 C6 04 08 00 89 05 FE 99
3s07 C6 04 08 00 89 1E FE 80
Buzzer Voice
Low07 C6 04 08 00 8C 02 FE 99
Middle: 07 C6 04 08 00 8C 01 FE 9A
High: 07 C6 04 08 00 8C 00 FE 9B
Buzzer Type
*Passive Buzzer: 08 C6 04 08 00 F2 D8
00 FD 5C
Active Buzzer: 08 C6 04 08 00 F2 D8
01 FD 5B