www.hzgrow.com
Table 6-2
Factory Default Configuration:08 C6 04
08 00 F2 FF 00 FD 35
4s:07 C6 04 08 00 88 28 FE 77
10s:07 C6 04 08 00 88 64 FE 3B
Single Scan Time(Scanning
duration)Quickly Set Up
Infinite:08 C6 04 08 00 F2 FA 00 FD 3A
3s:08 C6 04 08 00 F2 FA 03 FD 37
5s:08 C6 04 08 00 F2 FA 05 FD 35
10s:08 C6 04 08 00 F2 FA 0A FD 30
15s:08 C6 04 08 00 F2 FA 0B FD 2F
20s:08 C6 04 08 00 F2 FA 0C FD 2E
30s:08 C6 04 08 00 F2 FA 0D FD 2D
60s:08 C6 04 08 00 F2 FA 0E FD 2C
Button Holding:07 C6 04 08 00 8A 00
FE 9D
Button Trigger:07 C6 04 08 00 8A 02
FE 9B
Continuous scanning:07 C6 04 08 00
8A 04 FE 99
Automatic Induction: 07 C6 04 08 00 8A
09 FE 94
Host:07 C6 04 08 00 8A 08 FE 95
0s:07 C6 04 08 00 89 00 FE 9E
0.5s: 07 C6 04 08 00 89 05 FE 99
3s:07 C6 04 08 00 89 1E FE 80
Low:07 C6 04 08 00 8C 02 FE 99
Middle: 07 C6 04 08 00 8C 01 FE 9A
High: 07 C6 04 08 00 8C 00 FE 9B
*Passive Buzzer: 08 C6 04 08 00 F2 D8
00 FD 5C
Active Buzzer: 08 C6 04 08 00 F2 D8
01 FD 5B