Operation Modes12 Operation Modes12
12.1 Normal Mode
In this mode, the inverter works normally and LED turns green.
1.
Whenever
the DC voltage is higher than 150Vdc, inverter converts power to grid
as generated by the PV panels;
2.
Whenever
the DC voltage is lower than 150Vdc, the inverter will work in waiting
state and attempt to connect the grid. In waiting state the inverter consumes just
enough power generated by the PV panel to monitor the internal system status;
NOTICE
The inverter starts up automatically when the DC power from
the PV panel is sufficient.
12.2 Fault Mode
The internal intelligent controller can continuously monitor and adjust the system
status. If inverter finds any unexpected conditions such as system fault and inverter
fault, the fault information will be displayed on the LCD. In fault mode the LED turns
red.
NOTICE
Detailed fault information refers to 13. Trouble shooting.
12.3Shutdown Mode
Inverters automatically stop running during periods of little or no sunlight. In
shutdown mode the inverters take no power from the grid and panel, and the LCD
and LED turns off.
NOTICE
If the PV string DC voltage is too low, the inverter will also
turn to Shutdown Mode.
De-rating Operation 13De-rating Operation 13
Temperature
The inverter will monitor the temperature of the heat-sink. Once the temperature
exceeds 75°C (167°F) ,the system will reduce the output power until the temperature
drops under the critical value. The inverter will shut down the power output to the
grid if the temperature reaches 85°C (185°F). If this occasion happens often, it is
necessary to check whether the inverter is mounted at an appropriate place with
good ventilation and not directly exposure to the sunshine.
Manufacturer Warranty 14Manufacturer Warranty 14
This certificate represents a 10 year warranty for the Growatt inverter products listed
below. Possession of this certificate validates a standard factory warranty of 5 years
from the date of purchase.
14.1 Warranted products
This warranty is applicable solely to the following products:
Growatt1500-US;Growatt2000-US;Growatt3000-US
Growatt3600MTL-US;Growatt4200MTL-US;Growatt5000MTL-US
14.2 Limited Product Warranty
(Applicable under normal application, installation, use and service conditions)
Growatt warrants the above listed products to be free from defects and/or failure
specified for a period not exceeding ten (10) years from the date of sale as shown in
the Proof of Purchase to the Original purchaser.